IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

$139.00

SKU: 1600223163385 Brand:

Description

The IKURA THA1-7556X-TP is a high-performance industrial AC axial cooling fan engineered for rigorous thermal management in demanding B2B environments. Designed with a robust aluminum die-cast frame and precision dual ball bearings, this unit ensures extended operational longevity and stable airflow under continuous load. The integration of a Normally Open (N/O) sensor driver provides critical real-time feedback to system controllers, enabling immediate fault detection and preventing catastrophic overheating in sensitive electronic enclosures. The ‘TP’ designation confirms built-in thermal protection, automatically safeguarding the motor coil from extreme temperature spikes.

Technical Specifications:
Brand: IKURA
Model Number: THA1-7556X-TP
Product Category: Industrial AC Axial Fan
Rated Voltage: 200V AC (Single Phase)
Operating Frequency: 50/60 Hz
Power Consumption: 43W (50Hz) / 40W (60Hz)
Physical Dimensions: 170 x 150 x 55 mm
Bearing Architecture: Precision Dual Ball Bearing
Motor Protection: Integrated Thermal Protection (TP)
Sensor Type: Normally Open (N/O) Rotation/Fault Sensor
Frame Construction: Die-Cast Aluminum
Impeller Material: UL94V-0 Flame Retardant Plastic
Operating Temperature Range: -10°C to +60°C
Estimated Weight: 1.1 kg

Industrial Application & Technical Compatibility:
This specific cooling fan is highly critical for large-scale factory automation panels, CNC machining centers, and high-capacity inverter drives where continuous heat dissipation is mandatory. The 170x150x55mm form factor provides a high volumetric airflow (m³/min) necessary to maintain optimal ambient temperatures inside densely packed control cabinets. The N/O sensor driver integrates seamlessly with PLC logic to trigger automated shutdown sequences or alarms if fan rotation fails, thereby protecting expensive drive components from thermal degradation.

Procurement & Lifecycle Value:
Sourcing this Original Engineering component guarantees exact Technical Compatibility with existing IKURA installations, eliminating the need for retrofitting or structural modifications. Maintaining standard Lead Time protocols for this exact THA1-7556X-TP model ensures minimal downtime for critical manufacturing infrastructure, maximizing overall equipment effectiveness and extending the lifecycle of adjacent sensitive electronics.

Key Attributes
Voltage: 200V
Electric current type: AC
Mounting type: Free Standing
Warranty: 1 Year
Blade material: Plastic
Customized support: OEM
After-sales service provided: Online support
Place of origin: Japan
Brand name: Ikura
Model number: THA1-7556X-TP-N/O
Voltage: 200V
POWER: 43/40W
Current type: AC
Frequency: 50/60Hz
Bearing type: 2 ball bearings

Packaging and Delivery
Packaging Details: Carton Package
Port of dispatch: Tianjin port
Selling Units: Single item

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

IKURA THA1-7556x-TP N/O 200V AC 43/40W 170x150x55mm Sensor Driver Industrial Axial Fan

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Fans Maintenance and upkeep

1. The use environment should always be kept clean and tidy, the surface of the fan should be kept clean, there should be no sundries in the inlet and outlet air outlets, and the dust and other sundries in the fan and pipes should be cleaned regularly;

2. The fan can only operate under the condition that it is completely normal, and at the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient and the voltage is stable.

3. During the operation of the fan, if it is found that the fan has abnormal sound, the motor is seriously heated, the shell is live, the switch trips, and cannot be started, it should be stopped immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan, and a test run should be carried out for about five minutes after the overhaul to confirm that there is no abnormal phenomenon before starting the operation;

4. The fan should be stored in a dry environment to avoid moisture on the motor. When the fan is stored in the open air, there should be defensive measures. In the process of storage and handling, the fan should be prevented from bumping to avoid damage to the fan.

FAQ

JinBuy is a trusted supplier of industrial and home appliance spare parts, offering high-quality components for cooling systems, HVAC units, vacuum cleaners, printers, compressors, CNC machines, and more. We provide reliable products, competitive prices, and fast worldwide delivery.