Delta Heat Pump GTM019FUA07R-V 230V EC 190mm 85W 6.75A 3100RPM IP54 AHU Air Handling Unit Centrifugal Fan

$589.00

SKU: 1600879385070 Brand:

Description

The Delta GTM019FUA07R-V is a high-efficiency Electronically Commutated (EC) centrifugal cooling fan engineered for advanced thermal management in industrial HVAC applications. Designed specifically for Air Handling Units (AHU) and commercial heat pump systems, this backward-curved centrifugal fan delivers optimal aerodynamic performance while minimizing energy consumption through advanced motor control logic.

Technical Specifications:
Brand: Delta Electronics
Model Number: GTM019FUA07R-V
Fan Architecture: Backward Curved Centrifugal
Motor Technology: Electronically Commutated (EC)
Nominal Voltage: 230 VAC
Operating Frequency: 50/60 Hz
Impeller Diameter: Ø 190 mm
Power Consumption: 85 W
Nominal Current: 6.75 A
Rated Speed: 3100 RPM
Ingress Protection: IP54
Operating Temperature: -25 °C to +60 °C
Insulation Class: Class B
Weight: 1.65 kg
Control Input: PWM / 0-10V Analog

Original Engineering and Design:
Manufactured by Delta Electronics, this EC fan integrates a highly efficient brushless DC motor with onboard AC-to-DC conversion and intelligent electronic commutation. This Original Engineering ensures precise, stepless speed control, allowing the system to adapt dynamically to varying thermal loads without the energy losses associated with traditional AC motors. The IP54 environmental rating guarantees robust protection against dust accumulation and splashing water, ensuring continuous, reliable operation in demanding industrial environments.

Industrial Application:
The GTM019FUA07R-V is specifically deployed in high-static-pressure environments such as commercial heat pumps, precision air conditioning, and modular Air Handling Units (AHU). Its Ø 190 mm impeller and 3100 RPM rotational speed provide the necessary volumetric flow rate to overcome system impedance in densely packed heat exchangers. By maintaining a consistent and controlled airflow, this centrifugal fan prevents compressor overheating and ensures optimal thermodynamic cycles in critical climate control infrastructure.

Lifecycle and Procurement:
Ensuring strict Technical Compatibility with existing Delta-driven HVAC infrastructure, this component serves as a direct drop-in replacement to restore original system efficiency and acoustic performance. We maintain an optimized supply chain to minimize Lead Time, ensuring your critical facility operations and thermal management systems experience minimal downtime during scheduled maintenance or emergency repairs.

Key Attributes
Mounting: Free Standing
Voltage: 230V
Blade Material: Plastic
Customized support: OEM, ODM
Warranty: 1 Year
After-sales Service Provided: Online support
Model number: GTM019FUA07R-V
Place of origin: China
Brand name: Delta
Product name: GTM019FUA07R-V
Current: 6.75A
Voltage: 230V
Speed: 3100 rpm
Air flow: 443CFM
IP rating: IP54
Bearing type: Ball bearing
Electrical leads: Lead wire
Insulation class: B
Life expectance: 60,000 hrs at 40 ℃ / 15 ~ 65 %RH

Packaging and Delivery
Selling Units: Single item
Single package size: 36X36X35 cm
Single gross weight: 6.000 kg

Delta Heat Pump GTM019FUA07R-V 230V EC 190mm 85W 6.75A 3100RPM IP54 AHU Air Handling Unit Centrifugal Fan

Delta Heat Pump GTM019FUA07R-V 230V EC 190mm 85W 6.75A 3100RPM IP54 AHU Air Handling Unit Centrifugal Fan

Delta Heat Pump GTM019FUA07R-V 230V EC 190mm 85W 6.75A 3100RPM IP54 AHU Air Handling Unit Centrifugal Fan

Delta Heat Pump GTM019FUA07R-V 230V EC 190mm 85W 6.75A 3100RPM IP54 AHU Air Handling Unit Centrifugal Fan

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Fans Maintenance and upkeep

1. The use environment should always be kept clean and tidy, the surface of the fan should be kept clean, there should be no sundries in the inlet and outlet air outlets, and the dust and other sundries in the fan and pipes should be cleaned regularly;

2. The fan can only operate under the condition that it is completely normal, and at the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient and the voltage is stable.

3. During the operation of the fan, if it is found that the fan has abnormal sound, the motor is seriously heated, the shell is live, the switch trips, and cannot be started, it should be stopped immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan, and a test run should be carried out for about five minutes after the overhaul to confirm that there is no abnormal phenomenon before starting the operation;

4. The fan should be stored in a dry environment to avoid moisture on the motor. When the fan is stored in the open air, there should be defensive measures. In the process of storage and handling, the fan should be prevented from bumping to avoid damage to the fan.

FAQ

JinBuy is a trusted supplier of industrial and home appliance spare parts, offering high-quality components for cooling systems, HVAC units, vacuum cleaners, printers, compressors, CNC machines, and more. We provide reliable products, competitive prices, and fast worldwide delivery.