FFB0824EHE-R00 Delta Original 8038 fan

$6.43

SKU: 886096522835 Brand:

Description

Manufacturer: Delta Electronics
Model Number: FFB0824EHE-R00
Series: FFB High Performance
Dimensions: 80 x 80 x 38 mm
Rated Voltage: 24V DC
Operating Voltage Range: 14.0 to 26.4V DC
Rated Current: 0.75A
Maximum Input Current: 1.13A
Rated Power: 18.00W
Rated Speed: 5700 RPM
Maximum Airflow: 80.16 CFM (2.270 m³/min)
Maximum Static Pressure: 17.78 mmH2O (0.700 inH2O)
Noise Level: 52.5 dB-A
Bearing Type: Precision Dual Ball Bearing
Signal Output: R00 Locked Rotor Alarm (3-Wire)
Termination: Lead Wires (Red/Black/Blue)
Frame Material: UL 94V-0 Plastic
Impeller Material: UL 94V-0 Plastic
Operating Temperature: -10°C to +70°C
Service Life: 70,000 Hours at 40°C L10
Weight: 170g
Safety Certifications: UL, CUL, TUV, CE
Original Engineering: Genuine Delta thermal solution utilizing high-density winding and optimized blade geometry for high-static pressure applications.
Technical Compatibility: Direct replacement for 8038 form factor industrial cooling units requiring 24V DC input and alarm monitoring.
Industrial Application: The FFB0824EHE-R00 is specifically designed for high-impedance environments such as industrial frequency converters and high-density server enclosures. The R00 sensor provides a critical fail-safe by triggering a system alarm upon rotor lock, preventing catastrophic thermal runaway in power electronics. Its 38mm depth allows for the high torque and pressure necessary to push air through restrictive dust filters and dense heat sink arrays.
Lead Time: Available for immediate dispatch to minimize industrial downtime.

FFB0824EHE-R00 Delta Original 8038 fan

FFB0824EHE-R00 Delta Original 8038 fan

FFB0824EHE-R00 Delta Original 8038 fan

FFB0824EHE-R00 Delta Original 8038 fan

FFB0824EHE-R00 Delta Original 8038 fan

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Fans Maintenance and upkeep

1. The use environment should always be kept clean and tidy, the surface of the fan should be kept clean, there should be no sundries in the inlet and outlet air outlets, and the dust and other sundries in the fan and pipes should be cleaned regularly;

2. The fan can only operate under the condition that it is completely normal, and at the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient and the voltage is stable.

3. During the operation of the fan, if it is found that the fan has abnormal sound, the motor is seriously heated, the shell is live, the switch trips, and cannot be started, it should be stopped immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan, and a test run should be carried out for about five minutes after the overhaul to confirm that there is no abnormal phenomenon before starting the operation;

4. The fan should be stored in a dry environment to avoid moisture on the motor. When the fan is stored in the open air, there should be defensive measures. In the process of storage and handling, the fan should be prevented from bumping to avoid damage to the fan.

FAQ

JinBuy is a trusted supplier of industrial and home appliance spare parts, offering high-quality components for cooling systems, HVAC units, vacuum cleaners, printers, compressors, CNC machines, and more. We provide reliable products, competitive prices, and fast worldwide delivery.